  • Introduction
Introduction

■ Approvals

The following table lists the certificates and standards that the product may comply with. For details about the acquired certificates, see the certification marks on the product nameplate.

 

Certification

Directives

Standard

CE

EMC directives

2014/30/EU

EN 61800-3

LVD directives

2014/35/EU

EN 61800-5-1

RoHS directives

2011/65/EU

EN 50581

TUV

-

EN 61800-5-1

UL

-

UL508C/UL61800-5-1

C22.2 No.14-13

■ Ratings

Table 1-1  Ratings of MD290T18.5G/22P to MD290T75G/90P

Voltage Class

380 to 480 VAC

MD290TxxG/xxP(B1)(-INT)

18.5G/22P

22G/30P

30G/37P

37G/45P

45G/55P

55G/75P

75G/90P

Dr ive Input

Rated Input Voltage

Three-phase 380 to 480 V, -15% to +10%

Rated Input Current, [A]

G type

49.5

59

57

69

89

106

139

P type

59

65.8

71

86

111

143

167

Rated Input Frequency

50/60 Hz, ±5%

Power

Capacity, [kVA]

G type

45

54

52

63

81

97

127

P type

54

60

65

79

102

131

153

Drive Output

 

Applicable Motor

G type [kW]

18.5

22

30

37

45

55

75

G type [HP]

25

30

40

50

60

75

100

P type [kW]

22

30

37

45

55

75

90

P type [HP]

30

40

50

60

75

100

120

Output

Current, [A]

G type

37

45

60

75

91

112

150

P type

45

60

75

91

112

150

176

Default Carrier Frequency, [kHz]

6

6

6

5

5

4

3

Overload Capacity

G type: 150% for 60 Sec,

P type: 110% for 60 Sec

Output Voltage

Three phase 0 V to input voltage

Max. Output Frequency

500 Hz

Braking  Resistor

Recommended Power, [kW]

4

4.5

6

7

9

11

15

 

Recommended

Resistance, Min.  [Ω]

 

24

 

24

 

19.2

 

14.8

 

12.8

 

9.6

 

6.8

Therma l Design

Thermal design power, [kW]

 

0.478

 

0.551

 

0.694

 

0.815

 

1.01

 

1.21

 

1.57

Air flow, [CFM]

 

51.9

 

57.4

 

118.5

 

118.5

 

122.2

 

122.2

 

218.6

Enclosure

IP20

 

 

Table 1-2  Ratings of MD290T90G/110P to MD290T160G/200P

Voltage Class

380 to 480 VAC

MD290TxxG/xxP(-INT)

90G/110P

110G/132P

132G/160P

160G/200P

Dr ive Input

Rated Input Voltage

Three-phase 380 to 480 V, -15% to +10%

Rated Input Current, [A]

G type

164

196

240

287

P type

198

239

295

359

Rated Input Frequency

50/60 Hz, ±5%

Power

Capacity, [kVA]

G type

150

179

220

263

P type

181

219

270

328

Drive Output

 

Applicable Motor

G type [kW]

90

110

132

160

G type [HP]

120

150

180

220

P type [kW]

110

132

160

200

P type [HP]

150

180

220

267

Output

Current, [A]

G type

176

210

253

304

P type

210

253

304

377

Default Carrier Frequency, [kHz]

3

3

3

3

Overload Capacity

G type: 150% for 60 Sec,

P type: 110% for 60 Sec

Output Voltage

Three phase 0 V to input voltage

Max. Output Frequency

500 Hz

Braking

Resistor

Recommended Power, [kW]

18

22

26

32

 

Recommended Resistance, Min. [Ω]

 

5.3

 

5.3

 

3.5

 

3.5

Therma l Design

 

Thermal design power,  [kW]

 

1.81

 

2.14

 

2.85

 

3.56

Air flow, [CFM]

287.2

342.2

547

627

Enclosure

IP20

 

Table 1-3  Ratings of MD290T200G to MD290T280G and MD290T220P to MD290T315P

Voltage Class

380 to 480 VAC

Model: MD290Txxxx(-L)**(-INT)

200G

220P

220G

250P

250G

280P

280G

315P

Dr ive Input

Rated Input Voltage

Three-phase 380 to 480V, -15% to +10%

Rated Input Current, [A]

365

410

410

456

441

507

495

559

Power Capacity, [kVA]

334

375

375

417

404

464

453

511

Rated input frequency

50/60 Hz, ±5%

Drive Output

Applicable Motor, [kW]

200

220

220

250

250

280

280

315

Output Current, [A]

377

426

426

465

465

520

520

585

Default carrier frequency, [kHz]

3

3

3

3

3

3

3

3

Overload Capacity

G type: 150% for 60 Sec

P type: 110% for 60 Sec

Output Voltage

Three phase 0 V to input voltage

Max. output frequency

500 Hz

Braking

Resistor

Recommended Power, [kW]

38

38

42

42

48

48

54

54

Recommended Resistance, min.  [Ω]

2.9

2.9

2.7

2.7

2.3

2.3

2.1

2.1

Thermal

Design

Thermal design power,  [kW]

4.15

4.55

5.06

5.33

5.69

6.31

6.91

7.54

Air flow, [CFM]

638.4

722.5

789.4

882

645

860

860

860

Enclosure

IP00

 

 

Table 1-4  Ratings of MD290T315G to MD290T450G and MD290T355P to MD290T500P

Voltage Class

380 to 480 VAC

Model: MD290Txxxx(-L)**(-INT)

315G

355P

355G

400P

400G

450P

450G

500P

Dr ive Input

Rated Input Voltage

Three-phase 380 to 480V, -15% to +10%

Rated Input Current [A]

565

624

617

708

687

782

782

840

Power Capacity, [kVA]

517

571

565

647

629

715

716

768

Rated input frequency

50/60 Hz, ±5%

Drive Output

Applicable Motor, [kW]

315

355

355

400

400

450

450

500

Output Current, [A]

585

650

650

725

725

820

820

880

Default carrier frequency, [kHz]

3

3

3

3

3

3

3

3

Overload Capacity

G type: 150% for 60 Sec (For MD290T450G, the capacity is 130%.)

P type: 110% for 60 Sec

Output Voltage

Three phase 0 V to input voltage

Max. output frequency

500 Hz

Braking

Resistor

Recommended Power, [kW]

54

60

69

69

78

78

87

87

Recommended Resistance, min.  [Ω]

2.1

1.9

1.7

1.7

1.5

1.5

1.3

1.3

Thermal

Design

Thermal design power,  [kW]

4.15

4.55

5.06

5.33

5.69

6.31

6.91

7.54

Air flow, [CFM]

638.4

722.5

789.4

882

645

860

860

860

Enclosure

IP00

 

■ Technical Specifications

Table 2-3 Technical specifications of MD290

Item

Description

Standard functions

Input frequency resolution

Digital setting: 0.01 Hz

Analog setting: Max. frequency x 0.025%

Control mode

Voltage/Frequency (V/F) control

Torque boost

Customized boost 0.1 % to 30.0 %

V/F curve

     Straight-line V/F curve

     Multi-point V/F curve

     Square V/F curve

●     Complete V/F separation

     Half V/F separation

Ramp mode

     Straight-line ramp

     S-curve ramp

Four separate acceleration/deceleration time settings in the range of 0s to 6500s.

DC injection braking

DC injection braking frequency: 0 Hz to max. frequency

DC injection braking active time: 0.0s to 36.0s.

Current level of DC injection braking: 0% to 100%.

Jog running

Frequency range of jog running: 0.00 to 50.00 Hz

Acceleration/Deceleration time of jog running:0.0s to 6500.0s

Onboard multiple preset speeds

The system implements up to 16 speeds by using

simple PLC function or by using digital input signals.

Onboard PID

The system implements the proportionalegral-derivative (PID) function in the closed-loop control.

Automatic voltage regulation (AVR)

The system maintains a constant output voltage

automatically when the grid voltage changes through the permissible range.

Voltage limit and current limit

The system limits the output current and voltage

automatically during operation to prevent frequent or excessive trips.

Current limit and control

The system limits the current automatically during operation to prevent frequent overcurrent tripping.

Item

Description

Individualized functions

Power dip ride-through

Load feedback energy compensates for any voltage reduction, allowing the drive to continue to operate   for a short time during power dips.

Overcurrent fast prevention

The function helps to avoid frequent overcurrent faults.

Virtual I/O

Five groups of virtual digital input/outputs (DI/DO) support simple logic control.

Timing control

Time range: 0.0 to 6500.0 minutes

Dual-motor switchover

The drive have two groups of motor parameters and can control up to two motors.

Multiple field buses

The drive supports four field buses:

     Modbus-RTU

     PROFIBUS-DP

     CANlink

     CANopen

Motor overheat protection

Option: The optional input/output (I/O) extension   card allows AI3 to receive a signal from the motor temperature sensor input (PT100, PT1000) to

implement motor overheat protection.

User programmable function

Option: The optional programming card supports

secondary development in a programming environment compatible with the Inovance programmable logic controller (PLC).

Advanced PC software

Thee software allows users to configure some operating parameters, and provides a virtual

oscilloscope display that shows system status.

 

Item

Description

RUN

Command source

Allows different methods of switching between command sources:

●     Operating panel (keypad & display)

     Terminal I/O control

     Serial communication

Main frequency reference setting channel

Supports up to 10 frequency reference setting channels and allows different methods of switching between

frequency reference setting channels:

     Digital setting

●     Analog voltage reference

●     Analog current reference

     Pulse reference

●     Communication reference

Auxiliary frequency

reference setting channel

Supports up to 10 auxiliary frequency sources, and allows fine tuning of the auxiliary frequency and main & auxiliary  calculation.

Input terminals

Standard:

●     5 digital input (DI) terminals, one of which supports up to 100 kHz high-speed pulse inputs.

●     2 analog input (AI) terminals, one of which supports  only 0 to10 V input, and the other supports 0 to 10 V and 4 to 20 mA current input.

Expanded capacity:

●     5 digital input (DI) terminals.

●     1 AI terminal that supports –10 to 10 V voltage input   and PT100/PT1000 motor temperature sensor inputs.

Output terminals

Standard

●     1 high-speed pulse output terminal (open-collector) for a square-wave signal output in the frequency range 0   to 100 kHz

     1 digital output (DO) terminal

     1 relay output terminal

●     1 analog output (AO) terminal that supports either a current output in the range 0 to 20 mA or a voltage   output in the range 0 to 10 V.

Expanded capacity:

     1 extra DO terminal

     1 extra relay output terminal

●     1 extra AO terminal that supports either a current

output in the range 0 to 20 mA or a voltage output in the range 0 to 10 V.

 

Item

Description

Display and

operating panel

LED display

The LED display shows parameter values.

Key locking and function selection

●     Keys on the control panel can be locked or

partially locked electronically to prevent accidental operation.

●     The range of some functions can be limited to a permitted range to prevent incorrect settings.

Protections

Phase loss protection

     Input phase loss protection

●     Output phase loss protection

Instantaneous overcurrent protection

Stop when output current exceeds 250% of rated output current

Overvoltage protection

Stop when the main circuit DC voltage is above 820 V

Undervoltage protection

Stop when the main circuit DC voltage is below 350 V

Overheat protection

Protection triggered when the AC drive bridge gets overheated.

Overload protection

Stop after running at 150% of rated current for 60 seconds.

Overcurrent protection

Stop when output current exceeds 250% of rated current of the AC drive

Braking protection

     Braking unit overload protection

●     Braking resistor short-circuit protection

Short-circuit protection

●     Output inter-phase short-circuit protection

●     Output short-circuit to ground protection

Environment

Installation location

Install the AC Drive where it is indoors and protected from direct sunlight, dust, corrosive or combustible    gases, oil smoke, vapour, ingress from water or any  other liquid, and salt.

Altitude

Below 1000 m

If the altitude is above 1000 m, de-rate the drive according to                         

Max. 3000 m for LVD directive requirement.

Ambient temperature

–10°C to +40°C

If the ambient temperature is in the range of 40°C to 50°C, de-rate the drive according to                         .

Humidity

Less than 95% RH non-condensing.

Pollution degree

PD2

Overvoltage category

OVC III

Vibration

Less than 5.9 m/s² (0.6 g).

Storage temperature

–20°C to +60°C

 

 De-rating

The drive can be operated at above rated ambient temperature, altitude and default carrier frequency by de-rating  drive capacity.

  • Carrier Frequency De-rating

When carrier frequency of the drive is increased above default setting, you need to de-rate rated drive output current according to the following table:

Power

Carrier Frequency

Phd (kW)

3 kHz

4 kHz

5 kHz

6 kHz

7 kHz

8 kHz

18.5

100.0%

100.0%

100.0%

100.0%

95.7%

91.6%

22

100.0%

100.0%

100.0%

100.0%

95.5%

91.4%

30

100.0%

100.0%

100.0%

100.0%

93.5%

87.7%

37

100.0%

100.0%

100.0%

94.4%

89.0%

84.0%

45

100.0%

100.0%

100.0%

94.0%

88.6%

83.7%

55

100.0%

100.0%

94.1%

88.9%

84.0%

79.5%

75

100.0%

91.8%

84.2%

77.5%

-

-

90

100.0%

90.8%

82.3%

74.9%

-

-

110

100.0%

91.9%

84.4%

77.7%

-

-

132

100.0%

93.1%

86.7%

80.8%

-

-

160

100.0%

92.6%

85.7%

79.7%

-

-

200

100.0%

90.0%

81.0%

73.1%

-

-

220

100.0%

90.8%

82.5%

75.1%

-

-

250

100.0%

91.2%

83.2%

76.2%

-

-

280

100.0%

91.8%

84.3%

77.8%

-

-

315

100.0%

91.7%

83.9%

77.0%

-

-

355

100.0%

92.3%

85.2%

78.7%

-

-

400

100.0%

91.4%

83.6%

76.8%

-

-

 

  • Ambient Temperature De-rating

Drive operation between -10°C to 40°C is normal without de-rating. Operation between 40°C and 50°C requires output current de-rating. Rated output current must be de-rated for 1.5% per 1°C temperature rise. Permissible maximum temperature is 50°C.

(3) Altitude De-rating

The drive must be de-rated for an installation altitude of above 1000 meters because cooling effect available from ambient air reduces. Rated output current must bede-rated for 1% per 100 meters. Maximum altitude is 3000 meters.

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000

RELATED PRODUCT

Have questions about any products?

Our professional sales team are waiting for your consultation.
You can follow their product list and ask any questions you care about.

Get a Quote

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000